R26P with Web Relay

Doophone with Single Call Button
voys
Posts: 3
Joined: Fri Mar 23, 2018 9:05 pm

R26P with Web Relay

Postby voys » Wed Mar 28, 2018 7:35 pm

I am testing with an Akuvox R26P with firmware 26.0.2.144 and an 2N web relay but I can't get it working. My settings are in the attachment.

I don't know on what DTMF tone the web relay is reacting and what the Web Relay Action, Web Relay Key, Web Relay Extension should be. Is there a manual for this or can anyone point me in the right direction?
You do not have the required permissions to view the files attached to this post.

Akuvox_Dora
Posts: 9
Joined: Wed Oct 11, 2017 11:26 am

Re: R26P with Web Relay

Postby Akuvox_Dora » Thu Mar 29, 2018 2:40 pm

Hi voys,

The above attachment with incorrect settings. The "IP Address" option should be the Webrelay ip address here.
One more thing need check.Could you check the DTMF value of R26 built-in relay? The "Web Relay Key" should be kept the same as built-in relay DTMF code, so that it can open the built-in relay and webrelay at the same time.

voys
Posts: 3
Joined: Fri Mar 23, 2018 9:05 pm

Re: R26P with Web Relay

Postby voys » Fri Mar 30, 2018 8:05 pm

Still no success. I think I've got the right settings but I don't see any HTTP traffic in the PCAP's. I hear the relay in the R26P clicking when I press 1 on the phone. I've also tried to switch the web relay type do default but that also doesn't help. In the logging I see this:

Mar 30 13:35:08 : phone pid10665,tid10679,l6: CGALogic::Open Relay ,relay type is web relay

So it looks like the R26P is aware of the web relay.
You do not have the required permissions to view the files attached to this post.

voys
Posts: 3
Joined: Fri Mar 23, 2018 9:05 pm

Re: R26P with Web Relay

Postby voys » Fri Mar 30, 2018 9:21 pm

Almost there! I've got it working with no password on the web relay and the newest firmware (26.0.3.20). But I want to use a password on the web relay. I have to use this URL to work with the password: state.xml?noReply=1&relayState=2 But when I save the form the last part after the & is removed: state.xml?noReply=1

I have already tried to use an encoded & sign (%26) but that also doesn't help.

Akuvox_Jon
Posts: 59
Joined: Wed Oct 11, 2017 11:32 am

Re: R26P with Web Relay

Postby Akuvox_Jon » Mon Apr 02, 2018 4:22 pm

Hi Voys,

The web relay extension means that the web relay works only when receives the DTMF tone from the predefined extension.
I think it will work well if you leave the "web relay extension" blank.

thowa
Posts: 10
Joined: Tue Aug 07, 2018 5:18 am

Re: R26P with Web Relay

Postby thowa » Tue Aug 21, 2018 5:53 am

Hi all,

it might sound a bit silly but can anyone explin to me, what is a web relay?
Is it an additional (maybe 3rd party) piece of hardware or is it just on of the build in relas of the Akuvox?

Akuvox_Sean
Posts: 8
Joined: Fri Jul 06, 2018 10:13 am

Re: R26P with Web Relay

Postby Akuvox_Sean » Thu Aug 23, 2018 4:11 pm

Hi Thowa,
Web Relay is an additional piece of hardware like you said. It could applied to remote control especially in security lock system. It is not the build-in relays of Akuvox products. Of course Akuvox does have build-in relays, but sometimes web relay could be applied to specific situation and coorperate with Akuvox products to achieve specific purpose.
https://www.controlbyweb.com/webrelay/

thowa
Posts: 10
Joined: Tue Aug 07, 2018 5:18 am

Re: R26P with Web Relay

Postby thowa » Thu Aug 23, 2018 4:50 pm

that makes it clear to me.

Thanks a lot for the answer and the link

didi
Posts: 10
Joined: Sun Oct 28, 2018 12:38 am

Re: R26P with Web Relay

Postby didi » Sun Dec 02, 2018 1:07 am

Hi all,
this thread is a little bit old, but I got the same problem as voys: Every "Web Relay Action"-string I put into the web form is cutted after pressing submit. After the first parameter (login credentials) everything else is removed, it's not possible to add a second parameter (relay action) with "&".
I'm using this web relay: https://www.teracomsystems.com/ethernet ... cw122b-cm/
If I put the whole action string (with changed port, login, password and action, like: "http://device.ip.address:port/status.xml?a=admin:admin&pl1=1") in the "Action URL"-"open relay success" located in the phone menu, everything works fine. Drawback, the action is triggered for relay 1 and relay 2.

Best regards,
Didi

Akuvox_Jon
Posts: 59
Joined: Wed Oct 11, 2017 11:32 am

Re: R26P with Web Relay

Postby Akuvox_Jon » Tue Dec 04, 2018 10:40 am

Hi didi,

It is a pity that our devices are only compatible with the webrelay from control by web. See it at:
https://www.controlbyweb.com/webrelay/

As for the parameter removed issue, could you please let me know the firmware version please?

Also may I know where did you purchase our products? I will help to get corresponding latest firmware for you.

Or maybe it doesn't matter because it is not compatible with the web relay which you are using now?

Please be free to let me know if any further question.

Best Regards.